COMPACT HIGH VOLTAGE POWER SUPPLIES - Robust and efficient devices at an attractive price
The M-Power-Line series is a competitive, highly efficient, compact DC power supply with robust design. Combining simple operation and an easy to use multi-function display, these power supplies are well suited for applications in industry, science and research.
The M-Power-Line convinces with its robust design, high efficiency, compact dimensions and excellent price-performance ratio. By using a Power Factor Controller (PFC) the input voltage may vary from 100V to 254V. This means that the devices can be used anywhere in the world regardless of the typical national power supply system. The simple operation and easy readability of relevant characteristic values (target/actual/state/alarm message) make the devices particularly attractive for use in many branches of industry as well as research institutes.
Basic Series - Compact DC-High Voltage Power Supplies (HVDC)
POWER
Power range available in 200W / 500W / 1000W
VOLTAGE
Output voltage available in 10kV / 30kV / 50kV, Continuously adjustable from zero to maximum
APPLICATIONS
Laboratory power
Photomultiplier / Secondary electron muliplier
High-voltage test stands
Gas discharge / Plasma
Electrostatics
Sputtering
Capacitor / Insulations testing
Ion sources
Nuclear fusion research
Particle accelerators
FLEXIBLE CONTROLS WITH CONVENIENT MENU NAVIGATION
M-Power-Line models feature flexible and easy to operate local controls combined with a multifunction digital display that simultaneously shows both the output set points and actual measured values. HV outputs can be adjusted with voltage and current encoders with coarse and fine settings, with set point adjustment possible even with the output locked. The local control interface also allows the user to set the IP address, displays information about the unit, such as serial number, firmware version, operation hours, MAC address and internal status.
Other features include operating hours counter, device history (fault memory), streaming of actual values and states with timestamp, flash-over counter, over temperature device shutdown, and much more. The HV output is resistant to short circuits and flash-overs and can operate continuously into a short circuit. The M-Power-Line power supplies are suitable for both inductive and capacitive loads and for unlimited operation at both full and no load.
PROTECTIVE FUNCTIONS
Multiple temperature sensors monitor the main power components, and in the event of a fault, power circuits are shut down and a fault message is displayed.
STANDARD DIGITAL INTERFACES
Standard integrated LAN and USB interfaces are located on the rear panel. This ensures the power supply can be controlled and maintained remotely and also allows multichannel communication with the unit using checksumprotected data transmission.
TYPE OVERVIEW
TYPE | POLARITY (+/-) | POWER (W) | VOLTAGE (kV) | CURRENT (mA) | RIPPLE (Vp-p) | MAX STORED ENERGY (J) |
MPL 200-10000 POS | positive | 200 | 10 | 20 | 10 | 1,1 |
MPL 200-10000 NEG | negative | 200 | 10 | 20 | 10 | 1,1 |
MPL 500-10000 POS | positive | 500 | 10 | 50 | 10 | 1,7 |
MPL 500-10000 NEG | negative | 500 | 10 | 50 | 10 | 1,7 |
MPL 1000-10000 POS | positive | 1000 | 10 | 100 | 10 | 3,1 |
MPL 1000-10000 NEG | negative | 1000 | 10 | 100 | 10 | 3,1 |
MPL 200-30000 POS | positive | 200 | 30 | 7 | 30 | 2,4 |
MPL 200-30000 NEG | negative | 200 | 30 | 7 | 30 | 2,4 |
MPL 500-30000 POS | positive | 500 | 30 | 17 | 30 | 2,4 |
MPL 500-30000 NEG | negative | 500 | 30 | 17 | 30 | 2,4 |
MPL 1000-30000 POS | positive | 1000 | 30 | 33 | 30 | 3,5 |
MPL 1000-30000 NEG | negative | 1000 | 30 | 33 | 30 | 3,5 |
MPL 200-50000 POS | positive | 200 | 50 | 4 | 50 | 3,5 |
MPL 200-50000 NEG | negative | 200 | 50 | 4 | 50 | 3,5 |
MPL 500-50000 POS | positive | 500 | 50 | 10 | 50 | 3,4 |
MPL 500-50000 NEG | negative | 500 | 50 | 10 | 50 | 3,4 |
MPL 1000-50000 POS | positive | 1000 | 50 | 20 | 50 | 4,9 |
MPL 1000-50000 NEG | negative | 1000 | 50 | 20 | 50 | 4,9 |
Technical Features
Modern operating unit with convenient menu navigation
AC input (flexible use)
DC output (safe and reliable operation)
Fan control (low-noise operation)
Protective functions (maximum safety)
Digital interfaces as standard
Additional device functions
Operating hours counter, device history (error memory), streaming of monitor values and states with time stamp, flashover counter, overtemperature shutdown of the device and much more.
TECHNICAL DATA
- Average output power: 200W, 500W, 1000W
- Output voltage range: See table “Overview of types”; variable from 0.1% to 100% of rated voltage
- Output current range: See table “Overview of types”; variable from 0.1% to 100% of rated current
- AC input: Wide range 99-253V AC single phase, 47-63Hz
- AC input connector: IEC60320 C20 receptacle
- Power factor: > 0.95 at full load at nominal AC line
- Efficiency: 85% - 90% at full load
- Safety: CE mark, EN61010-1 compliant. The power supply unit may only be operated by trained and qualified personnel.
- EMC: EN61000-6-2 and EN61000-6-3
- Output control: Continuous adjustment from 0 to rated voltage/current by front panel mounted encoders with coarse and fine adjustment settings
- Response time: < 500ms for 10% - 90% or 90% - 10% of rated output voltage at rated load
- Polarity: Specify positive (P) or negative (N) when ordering, grounded return
- Set point resolution: ±0.1% of rated
- Line regulation (current & voltage): ±0.01% for ±10% AC line voltage variation
- Load regulation (current & voltage): ±0.1% no load to full load
- Voltage ripple (0 - 10MHz): 0.1% peak to peak
- Stability: ±0.1% over 8 hours under constant conditions after 30 min. warm up
- Temperature coefficient: ±0.1% per °C
- Ambient temperature: 0°C to +40°C operating, 0°C to +60°C storage
- Humidity: 0% - 80% at 0°C - 31°C, 0% - 50% at 31°C - 40°C non-condensing
- Cooling: Forced air cooling with variable speed fan
- Altitude: Operating: 6,500ft (2.000m)
- HV output connection: Mating HV connector and 3m cable supplied
- HV insulating medium: Outputs ≤ 10kV are air insulated, ≥ 30kV use solid dielectric silicone encapsulation
- Front panel: Voltage and current encoders, power switch, HV ON/OFF switch, multi-function display shows actual outputs, set points, set/display IP address, unit status, MAC address, baud rate
- LAN interface (standard): Full duplex with 5 simultaneous connections possible via Ethernet, IP address configurable via front panel display, transfer speed of 10/100Mbit/s. TCP/IPv4 protocol
- USB interface (standard): Virtual COM port on PC side, 115k Baud
- Mechanical: 2HU height (3.5") rackmount package x 17.9" deep x 17.5" wide
- Weight: 10kV models – approx. 10 kg / 30kV - 50kV models – approx. 14 kg
- Protection: Open/short circuits, arcs, overtemp, flashover