Analisador de Qualidade de Energia AEMC PowerPad Jr 8230

    Preço sob consulta

    Em estoque


The PowerPad® Jr. Model 8230 is a single-phase power quality analyzer that is easy-to-use, compact and shock-resistant. It is intended for technicians and engineers to measure and carry out diagnostic work and power quality work on single- or three-phase balanced load networks. The Model 8230 is also available in Kits with user selectable current probes.


FEATURES

- Measures up to 660Vrms or Vdc
- Measures up to 6500Aac or 1400Adc(probe dependent)
- Displays Min, Max and Average Volts and Amps,Crest Factor, Peak value and K-Factor
- Calculates and displays Watts, VARs and VA,Power Factor and Displacement Power Factor forsingle-phase and balanced three-phase
- Measures and records power systems (kW, VA, kVAR)
- Energy metering (kAh, VARh, kWh)
- Displays total harmonic distortion(THD-F and THD-R) for voltage and current
- Displays individual harmonic values and % for Voltsand Amps through the 50th harmonic
- Captures, displays and stores inrush currentwaveforms and statistics
- Stores up to eight screen captures
- Stores up to 1MB of trend recorded data
- Configurable from DataView® software or front panel
- Download stored data to DataView® software viaoptical USB port (included)
- Captures up to 4096 alarm events from up to10 different thresholds
- Displays and records up to 17 different power quality parameters
- Includes FREE DataView® software for configuringdata storage, real-time waveform display, analysisand report generation
- The Max and Min RMS measurements are calculated every half-period


SPECIFICATIONS

MODEL: 8230
Voltage (TRMS): Phase-to-Phase - 660V;  Phase-to-Neutral - 600V
Current (TRMS): MN Clamp - 5mA to 6A/120A or 2 to 240A; MR Clamp - 10 to 1000A AC, 10 to 1400A DC; SR Clamp - 3 to 1200A; MiniFlex® - 10 to 1000A; AmpFlex®: 10 to 6500A(1)
Frequency (Hz): 40 to 70Hz
Other Measurements: kW, kVAR, PF, DPF, kWh, kVARh, kVAh, K-Factor, Flicker, Harmonic Phase Shift, Phase Rotation
Harmonics: THD-R, THD-F, V, A, VA, 1st to 50th, Direction, Sequence
Sampling Frequency: 256 samples/cycle
Data Storage: 1.5MB partitioned for waveforms, alarms and trend recording
Power Source: NiMH rechargeable battery pack (included) AC Supply: 120/230Vac(50/60Hz)
Battery Life: ≥8 hrs with display on ≥40 hrs with display off (recording mode)
Communication Port: Optically isolated USB
Display: 1/4 VGA (320 x 240) color LCD digital & graphical  display with adjustable brightness & contrast
Dimensions: 8.3 x 4.3 x 2.4" (211 x 108 x 60mm)
Weight: 1.9 lbs (0.88kg)
Safety Rating: EN 61010, 600V CAT III, IP54, Pollution Degree 2
(1)Crest factor at 6500 = 1


User Manual

Data Sheet

Brochure

Power Analyzers - Current Probe Specification Chart




Escreva um comentário

    Ruim           Bom

Perguntas e respostas

Receba as melhores ofertas e descontos exclusivos! Cadastre seu nome e e-mail aqui.

Acompanhe a Signum Technologies

Voltar ao Inicio
Signum Technologies © 2024
Desenvolvido por Ellis Agência Web Agência Ellis
Segurança e certificações
Segurança e certificações Segurança e certificações Segurança e certificações