Analisador de Potência Trifásica e Data Logger AEMC PowerPad III 8336
Preço sob consulta
The PowerPad® III Model 8336 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three- phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV.
The Model 8336 has 2GB of memory available for storing trend data. Additional internal memory is used to let you store alarms, transients, and snapshot data. The user can store up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input, and 10,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks or even months. Inrush current can also be captured and stored.
IMPORTANT WARRANTY NOTE: By registering online within 30 days from the date of purchase, your warranty will be extended to 3 years.
FEATURES
- Measurement of TRMS voltages up to 1000Vrms AC/DC for two-, three-, four- or five-wire systems
- Measurement of TRMS currents up to 10,000Arms(sensor dependent)
- Direct measurement of neutral current & voltage
- Frequency measurement (40 to 69Hz systems)
- Record and display trend data as fast as once per second for one month for up to 25 variables
- Transient detection on all V and I inputs (up to 210)
- Selectable PT and CT ratios
- Inrush current measurement
- Calculation of Crest Factors for V and A
- Calculation of the K-Factor for transformers
- Calculation of short-term and long-term flicker
- Calculation of the Three-Phase voltage unbalance
- Harmonic measurements (referenced to the fundamental or RMS value) for voltage, current or power, up to 50th harmonic
- Displays of harmonic sequencing and direction and calculation of overall harmonics
- Real-time display of Phasor diagrams including values and phase angles
- Monitors the average value of any parameter, calculated for a period from 1 sec to 15 min
- Measurement of active, reactive and apparent power per phase and their respective sum total
- Calculation of power factor, displacement power factor and tangent factor
- Recording, time stamping and characterization of disturbances (swells, sags and interruptions, exceedence of power and harmonic thresholds)
- Internal Trend Recording memory; Alarm, Photo and Transient Inrush memories are separate
- Measurement of energy VAh, varh, Wh & VADh
- The Max and Min RMS measurements are calculated every half-period
- 65μs/sample trend recording
- Includes FREE DataView® software for configuring datastorage, real-time display, analysis and report generation
MODEL INCLUDES: Carrying bag, soft carrying pouch, three current probes, four black 10ft voltage leads, 5ft USB cable, four black alligator clips, twelve color-coded input ID markers, NiMH battery, 110/230V power adapter with US power cord, SD-Card, and USB drive supplied with product user manual and DataView® software. Additional test kits are available
SPECIFICATIONS
MODEL: 8336
Input Terminals: 5 Voltage / 4 Current
Inputs: 4 Voltage / 4 Current
Voltage (TRMS AC+DC): 2 to 1000V
Voltage Ratio: up to 100,000:1
Current (TRMS AC+DC): MN93 - 500mA to 200A AC; MN193: 0.005 to 100A AC; SR193 Clamp: 1A to 1000A AC; AmpFlex® or MA193 Clamps: 100mA to 10000A AC; MR193 Clamp: 1A to 1300A AC/DC; SL261 Clamp: 50mA to 100A AC/DC; J93: 50 to 3500A AC/DC; Current Ratio: up to 60000:1
Frequency (Hz): 40 to 69Hz
Distribution Systems: 1P 2W, 1P 3W, 2P 2W, 2P 3W, 2P 4W, 3P 3W, 3P 4W and 3P 5W, 2 1/2 Element & Aron meters
Power Values: W, VA, var, VAD, PF, DPF, cos φ, tan φ
Energy Values: Wh, varh, VAh, VADh
Harmonics: 1st to 50th, Direction, Sequence; THD: 0 to 50, phase
Transient Mode: Up to 210
Inrush Mode: Yes, >10 min
Unbalance: Yes
Recording: Yes
Alarm Mode: 40 types; 10,000 recorded
Peak: Yes
Phasor Display: Automatic
Data Storage: 8GB SD card for storing trend data, 12.5MB internal memory for storing snapshot, transient, alarm and InRush data.
Display: Color 1/4 VGA TFT screen (320 x 240) diagonal 148mm
Snapshots: 50
Electrical Safety: IEC 61010, 1000V CAT III / 600V CAT IV
Protection: IP53
Languages: more than 27
Communication Interface: USB
Battery Life: >13 hrs, 25 hrs in Record Mode
Power Supply: 9.6V NiMH rechargeable battery pack (included) or external charger
Dimensions / Weight: 9.8 x 7.9 x 2.6" (250 x 200 x 67mm) / 4.3 lbs (1.95kg)
User Manual
Quick Start Guide
Data Sheet
Brochure
Power Analyzers - Current Probe Specification Chart